![]() ![]() The experience-based values for the pressure of the high-pressure and the low-pressure drum are selected and held constant during this step. By using exergy analysis, the initial data used to analyze the performance and identified which components of the system that has the potential to do the performance improvement. In addition to analyze the performance of each component (compressor, combustion chamber, turbine, heat recovery steam generator) of the Combined Cycle Power Plant CCPP Tanjung Priok, this study also analyzes the impact of changes in the operating costs of the power plant after optimizing the parameters (pinch point and steam drum pressure). ![]() These cycles are made of a gas turbine, a steam turbine and Heat Recovery Steam Generator (HRSG). In this paper, combination between pinch and exergy analysis for a 326 MW Combined Cycle Power Plant (CCPP) at Tanjung Priok is performed.